Sign In | Join Free | My burrillandco.com
Home > Automatic Voltage Stabilizer >

GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase

    Buy cheap GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase from wholesalers
     
    Buy cheap GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase from wholesalers
    • Buy cheap GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase from wholesalers
    • Buy cheap GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase from wholesalers

    GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase

    Ask Lasest Price
    Brand Name : HRD
    Model Number : GTZW
    Supply Ability : 1000PCS/ MONTHH
    Price : Negotiate
    Payment Terms : L/C, T/T
    Delivery Time : 4-6 weeks
    • Product Details
    • Company Profile

    GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase

    GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase


    1,Characteristics

    v LCD Large-screen

    Using large-screen LCD display, can shows dynamic display voltage, current, and all kinds of working condition.


    v Product Characteristics

    The speed of response time(regulating speed) is very fast, non-contact, anti-interference, no mechanical failure and wear of carbon brush, maintenance-free. Three-phase voltage regulating independently to ensure the balance of output voltage . Effectively protect the security of the precision equipment.


    v Precision (output accuracy) Can Be Adjusted

    All precision of the stabilizer is preset plus or minus 2%. According to different load demand can be adjusted plus or minus 3%, plus or minus 5%.


    v Manual Voltage Regulation

    According to production requirement, within the scope of the 10% rated voltage value, the stabilizer can set voltage arbitrarily for different electrical equipment.


    v Automatic Bypass Function

    Equipped with automatic bypass function, when the stabilizer fails,it can turn into the mains automatically, no affection for the production.


    v Delay Stabilizing Output Voltage Function

    Voltage Stabilizer boot or recover from a state of protection, would not be regulated immediately. But stay on only after users determine that the mains voltage are normal to ensure that the load equipment would not be damaged.


    v Automatic Output Function

    System preset is automatic output. When stabilizer connect to the mains, system detect that the power grid is normal, then it would delay 30 seconds, stabilizing output voltage automatically.


    v Modular Design, Easy to Replace and Repair

    Adopting modular design, regulating circuit and monitoring circuits independent to each other, all components are standard-normalization. Assembly,debugging, maintenance are more simple and quick.


    v Strong Load/Carrying Capacity

    When the short-time overload or short-circuit, the transformer would not be damaged to avoid coil burning fire. When overload 150%, stabilizer can withstand 90 seconds, 20 seconds for overload 200%.

    v Output High and Low Voltage Protection Function

    When monitoring circuit detect the output voltage beyond the upper or lower limit, voltage stabilizer can turn into the mains automatically, no affection for the production.


    v Lack of Phase/Phase Fault Protection Function

    When monitoring circuit detected phase failure, voltage regulator /stabilizer will cut off the output automatically and voice-alarm.


    Product Specification


    PhaseModelCapacity(KVA)Current(A)Size (mm)
    W*S*G
    Weight (kg)
    3phaseGTZW-S101015350×600×750140
    GTZW-S151522
    GTZW-S202030160
    GTZW-S303046180
    GTZW-S454568390×650×870195
    GTZW-S606090240
    GTZW-S7575113460×650×1200316
    GTZW-S100100152330
    GTZW-S150150228700×700×1600450
    GTZW-S200200300530
    GTZW-S2502503421100×800×2100630
    GTZW-S320320486720
    GTZW-S400400608810
    GTZW-S500500760910
    GTZW-S6006009121050
    GTZW-S80080012161800×1000×21001300
    GTZW-S1000100015201650
    GTZW-S1200120018241900
    GTZW-S1600160024311800×1000×2100
    GTZW-S200020003038
    GTZW-S250025003798

    3.Main Technical Index

    INPUTRated VoltagePhase Voltage AC220V,Line Voltage AC 380V
    Stabilized Voltage Range3P3W+G 380Vac+/-20-60%(customised avaiable)
    Frequency50HZ/60HZ
    OUTPUTRated VoltagePhase Voltage AC220V,Line Voltage AC 380V
    Center Voltage±7℅(can be adjusted)
    Output Accuracy±2℅
    Response Time≤5ms
    Stabilization Time≤100ms/Step
    Waveform DistortionDo not produce additional waveform distortion(Static)
    Efficiency≥99℅
    Three-phase Unbalance FactorThree-phase voltage balance automatically, incrementation≤2%
    PROTECTIONOvervoltageThe output phase voltage is higher than 10℅(242V),Uninterrupted to bypass
    UndervoltageThe output phase voltage is lower than 10℅(198V),Uninterrupted to bypass
    Pheas LossYes,uninterrupted to bypass
    OverloadElectric detection, overload 1 minute, the output would be cut off.
    Over-currentElectronic detection and circuit breaker dual protection.
    Short CircuitElectronic detection and circuit breaker dual protection.
    BypassManual bypass and automatic bypass.
    INSTRUCTIONVoltageA,B,C,∑ABC Three-phase shows respectively true and effective values
    CurrentA,B,C,∑ABC Three-phase shows respectively true and effective values
    Working StateAVR/Bypass
    AbnormalOver-voltage, under-voltage, over-load, fuse blowing
    CONTROL MODEDSP operate metering chip intelligent control technology
    WORKING MODEWith automatic voltage regulation and the bypass, two working mode.
    VOLTAGE REGULATION MODEThree-phase adjust voltage separately

    OVERLOAD CAPACITY


    3 times the rated current, 1 second, can be adapted to the resistive, inductive, capacitive and impact load; can withstand the instantaneous overload impact. Stabilizer continuously output the rated current. When temperature rise stably, overload 10% for 30 minutes is allowed. Short-term (5 minutes) overload current (1.6 times rated value) is also allowed.

    4. Main Material List


    Material NameQuantityManufacturerIntroductions
    ENCLOSURE1pcsHRD

    Adopt 2.0 Thick Cold-Roll Steel Sheets.Surface treatment:G139→Phosphating+PZ660 powder+powder coating

    (RAL7032)plastic spraying;

    DISPLAY1pcsHRDAdopt STH wide angle LCD display,reading clearly;steroscopical and direct.
    MAIN BOARD1pcsHRDDevelop PCB independently,stable circuitry;The main components adopt imported brand, like ”Infineon”, “ST”,“Fairchild”, “Toshiba”,etc.
    SING PHASE COMPENSATING TRANSFORER3PCSHRDThrough secondary vacuum dipping, and continuously bake for 10 hours under the high temperature of 130 ℃.Transformer insulation class F, heat resistance 155 ℃. All the withstanding voltage are 3500V/5mA/min;
    THREE-PHASE REGULATING TRANSFORMER3PCSHRD
    RELAY3PCSHRDAdopt domestic first-class brand,special customized for the Digital Control Voltage Stabilizer.

    FUSE


    3PCSMing RongAdopting domestic fuse, the first brand ”Ming Rong”company’s high quality products
    INPUT SWITCH1PCSSHIHLIN

    ABSORPTION

    RESISTENCE

    6PCSVILVA ELECTRONIC

    Industrial-grade resistance stable and durable


    durable



    6. Technology and Special Requirements

    1.With output manual bypass switch;

    2. Enclosure material:Baosteel(or Wuhan Iron and Steel Group Corp)2mm thick cold-roll steel sheets; 3 .Surface Treatment :G139→Phosphating+PZ660 powder+powder coating(RAL7032);

    4.Products manufacture in accordance with the law of the People's Republic of China industry standard ,Compensating AC Stabilizer Targets.


    7. Technical Documents

    Provide the complete technical file about the equipment :

    A.1pcs The whole machine quality certification.

    B.1pcs Product test report

    C.1pcs User Manual


    8. Quality Assurance and After-sales Service

    1)Equipment warranty period is 1 year from the date of delivery;

    2)During the warranty period,supplier offer technical support for free; When get the notice of the failure by the Party A, Party B should implement the warranty obligations; Reponse within 8 hours and the solution should be given without 24 hours to reduce the losses of Party A. If maintenance need other spare parts, Party B assist purchasing, installation and debugging, within 48 hours solve the problem.

    3)After the warranty period, the supplier provide user with timely, high-quality, favorable technical service and supply spare parts.


    9. Display


    10. Pictures


    Quality GTZW - S10 - 2000KVA automatic voltage stabilizers , digital voltage regulator Three Phase for sale
    Inquiry Cart 0